Target Gas & Sensing Principle | Target Gas | Ethylene Oxide (EO/ETO) | - | Specialized for EO detection; not compatible with other toxic gases |
| Sensing Principle | Electrochemical (Three-electrode Structure: Working/Counter/Reference Electrodes) | - | Ensures high selectivity and low signal drift |
Measurement Performance | Detection Range | 0 ~ 100 | ppm | Custom ranges (0~50 ppm, 0~200 ppm) available upon request |
| Resolution | ≤ 0.1 | ppm | Minimum detectable concentration change |
| Accuracy | ±5% FS (Full Scale) or ±2 ppm, whichever is larger | - | Tested under standard conditions (25℃, 1 atm, 50% RH) |
| Response Time (T90) | ≤ 30 | Seconds | Time to reach 90% of stable output signal |
| Recovery Time (T10) | ≤ 60 | Seconds | Time to drop to 10% of stable output signal |
Electrical Characteristics | Power Supply Voltage | 5.0 ± 0.2 | V (DC) | Regulated power required; avoid overvoltage |
| Operating Current | ≤ 50 | mA | Typical value during continuous operation |
| Output Signal Type | Option 1: Analog (4 ~ 20 mA DC); Option 2: Analog (0 ~ 5 V DC); Option 3: Digital (UART/I2C) | - | Select output type when ordering |
| Signal Linearity | ≥ 99% | - | Factory-calibrated; no external linearization needed |
Environmental Adaptability | Operating Temperature Range | -10 ~ 50 | ℃ | Avoid condensation or extreme temperature fluctuations |
| Storage Temperature Range | -20 ~ 60 | ℃ | Store in dry, dust-free environment |
| Operating Humidity Range | 15 ~ 90 | % RH | Non-condensing; humidity >90% RH may affect accuracy |
| Atmospheric Pressure Range | 86 ~ 106 | kPa | Suitable for most low-altitude industrial/medical sites |
Mechanical & Physical Specs | Housing Material | Option 1: ABS Plastic (Standard); Option 2: 316L Stainless Steel (Harsh Environment) | - | Stainless steel option resists corrosion |
| Gas Intake Mode | Option 1: Diffusion (Passive); Option 2: Pump-driven (Active) | - | Diffusion for general use; pump-driven for long-distance sampling |
| Overall Dimensions (L×W×H) | 45 × 30 × 20 (ABS version); 50 × 35 × 25 (Stainless Steel version) | mm | Excludes connector/probe; refer to 2D drawing for exact size |
| Weight | ≤ 30 (ABS version); ≤ 80 (Stainless Steel version) | g | Net weight (excluding cables/fittings) |
Lifespan & Maintenance | Typical Operational Lifespan | ≥ 2 | Years | Under continuous operation in clean air (EO concentration < 1 ppm); lifespan shortens in high-concentration EO |
| Calibration Interval | 3 ~ 6 | Months | Recommended for maintaining accuracy; use NIST-traceable EO calibration gas |