Sign In | Join Free | My spintoband.com |
|
Brand Name : CITY
Model Number : 1LEL 75C PM989-600A-CIT
Place of Origin : Britain
MOQ : 1
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 2200
Delivery Time : 3 days
Packaging Details : canning
Operating Principle : Catalytic Oxidation
Inboard Filter : To remove H2S
Inboard Filter Capacity : 1000 ppm hr minimum
Sensitivity : 31 ± 5 mV/%CH4 (TBA)
Product Description:
1LEL 75C PM989-600A-CIT Electrochemical Combustible Gas Sensor
Features:
The purpose of this document is to present the performance specification of the 1 LEL 75C Combustible Gas sensor.
This document should be used in conjunction with the 1 LEL 75 Characterisation Note, the Operating Principles (OP01), Instructions for Safe Use and the Product Safety Datasheet (PSDS 22).
The data provided in this document are valid at 20°C, 50% rH and 1013 mBar for 3 months from the date of sensor manufacture. For guidance on sensor performance outside of these limits, please refer to the 1 LEL 75 Characterisation Note.
Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles OP01 and the Instructions for Safe Use.
Schedule of Limitations (Denoted by U After the Certificate Number)
• The sensors have been evaluated for a service temperature range of -40°C to +60°C.
• With regard to thermal ignition, the sensors have been evaluated as suitable for Group I use or for
Group II use with temperature code T4 for the stated service temperature range for Ui = 5 V.
• For group I applications with Ui > 5 V, the sensors must be installed in an enclosure preventing ingress
of coal dust.
• The device has not been assessed for resistance to impact or drop. The device shall be installed in a
suitably certified enclosure, per type of protection and in accordance with IEC 60079-0.
• The device has an external non-metallic surface greater the 400 mm2. It is therefore at risk of buildup
of electrostatic charge. The device shall be installed within an enclosure and limited to 400 mm2 of
material exposure.
• With regard to breather thermal temperature, including safety factor of 1.2 - breather surface
Specifications:
Measurement range | 0-100% LEL |
Sensitivity (resistance ratio) | 31 ± 5 mV/%CH4 (TBA) |
Use time | 5 years in air |
Long Term Output Drift | <3% signal/month |
![]() |
YJJ 1LEL 75C PM989-600A-CIT Electrochemical Combustible Gas Sensor Images |