| Sign In | Join Free | My spintoband.com |
|
Brand Name : Honeywell
Model Number : HIH-4000-003
Place of Origin : Mexico
MOQ : 1
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 5000pcs
Delivery Time : 3-5work days
Packaging Details : Paper box
Price : Negotiable
RH range : 0% to 100%
RH accuracy : +/- 3.5%
Installation style : Through Hole
Output type : Analog
Working power supply current : 200 uA
Power supply voltage - minimum : 4 V
HIH-4000-003 HIH4000-003 Humidity Sensor Medical equipment
DESCRIPTION;
The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.
Direct input to a controller or other device is made possible by this sensor’s near linear voltage output. With a typical current draw of only 200 µA, the HIH-4000 Series is often ideally suited for low drain, battery operated systems.
Tight sensor interchangeability reduces or eliminates OEM production calibration costs. Individual sensor calibration data is available.
The HIH-4000 Series delivers instrumentation-quality RH (Relative Humidity) sensing performance in a competitively priced, solderable SIP (Single In-line Package).
Available in two lead spacing configurations, the RH sensor is a laser trimmed, thermoset polymer capacitive sensing element with on-chip integrated signal conditioning.
The sensing element's multilayer construction provides excellent resistance to most application hazards such as wetting, dust, dirt, oils and common environmental chemicals.
FEATURES:
Molded thermoset plastic housing
Near linear voltage output vs % RH
Laser trimmed interchangeability
Low power design
Enhanced accuracy
Fast response time Stable
low drift performance
Chemically resistant
POTENTIAL APPLICATIONS:
Refrigeration equipment
HVAC (Heating, Ventilation and Air Conditioning)
equipment
Medical equipment
Drying
Metrology
Battery-powered systems
OEM assemblies
| Parameter | Specification | Test Conditions |
|---|---|---|
| Sensor Type | Capacitive Humidity Sensor | - |
| Target Measurement | Relative Humidity (RH) | - |
| Humidity Measurement Range | 0% - 100% RH | Non-condensing |
| Humidity Accuracy | ±3% RH (20% - 80% RH) | At 25°C (77°F); typical value |
| ±5% RH (0% - 100% RH) | At 25°C (77°F); full range | |
| Temperature Coefficient of Humidity | ±0.04% RH/°C | 0°C - 60°C (32°F - 140°F) |
| Response Time (T63%) | < 8 seconds | Step change: 10% → 90% RH; 25°C |
| Output Type | Analog Voltage (ratiometric to supply voltage) | - |
| Supply Voltage Range | 4.0 V DC - 5.8 V DC | Recommended: 5.0 V DC |
| Supply Current | 100 μA (max) | During measurement |
| 10 μA (max) | Standby mode (if applicable) | |
| Operating Temperature Range | -40°C - 85°C (-40°F - 185°F) | - |
| Storage Temperature Range | -40°C - 85°C (-40°F - 185°F) | - |
| Output Voltage at 0% RH | 0.8 V DC (min) - 1.2 V DC (max) | At 5.0 V supply; 25°C |
| Output Voltage at 50% RH | 2.3 V DC (min) - 2.7 V DC (max) | At 5.0 V supply; 25°C |
| Output Voltage at 100% RH | 3.8 V DC (min) - 4.2 V DC (max) | At 5.0 V supply; 25°C |
| Long-Term Stability | < ±1% RH/year | Typical; under normal operating conditions |
| Package Type | 4-Pin DIP (Dual In-Line Package) | - |
| Weight | ~2.5 grams | Approximate value |


|
|
HIH-4000-003 HIH4000-003 Humidity Sensor For Medical equipment Images |