Sign In | Join Free | My spintoband.com
China ShenzhenYijiajie Electronic Co., Ltd. logo
ShenzhenYijiajie Electronic Co., Ltd.
The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates
Verified Supplier

4 Years

Home > Gas Sensor >

AA015-000 CNLH 2-electrode Electrochemical Gas Sensor Precision With 0-2 Ppm O2 Range

ShenzhenYijiajie Electronic Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

AA015-000 CNLH 2-electrode Electrochemical Gas Sensor Precision With 0-2 Ppm O2 Range

Brand Name : CITY

Model Number : AA015-000

Place of Origin : USA

MOQ : 1

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Delivery Time : 3-5workingdays

Packaging Details : Standard Package

Measurement Range : 0-2 Ppm O2

Purge Time : < 6 Hours

Output Signal : 13 -17 MV In Air With A 10Q Load Resistor

Maximum Overload : 1000 Ppm O2

Operating Principle : 2-electrode Electrochemical

Filter : None

Response Time (T95) : < 20 Seconds

Contact Now

Product Description:

Not only does this gas sensor provide accurate measurements, but it also boasts a reliable output signal of 13-17 mV in air with a 10Q load resistor. This ensures that you will always receive consistent readings, making it easy to monitor any changes in your oxygen levels.

For those concerned about overloading the sensor, the maximum overload for this gas sensor is 1000 ppm O2. This means that the CatEx 125 PR, LEL can handle high levels of oxygen without sacrificing accuracy or reliability.

Overall, the Gas Sensor - CatEx 125 PR, LEL is a top-of-the-line option for those looking to monitor oxygen levels in their environment. Its 2-electrode electrochemical operating principle, lack of filter, and precise measurement range make it an excellent choice for any setting. Plus, with its reliable output signal and high maximum overload, you can trust that this gas sensor will provide accurate readings no matter the circumstances.

Features:

  • Product Name: Gas Sensor
  • Maximum Overload: 1000 Ppm O2
  • Purge Time: < 6 Hours
  • Operating Principle: 2-electrode Electrochemical
  • Measurement Range: 0-2 Ppm O2
  • Output Signal: 13 -17 MV In Air With A 10Q Load Resistor

Gas Sensor with product number 6812950 is a CatEx 125 PR gas sensor.

Technical Parameters:

Response Time (T95) < 20 Seconds
Output Signal 13 -17 MV In Air With A 10Q Load Resistor
Maximum Overload 1000 Ppm O2
Operating Principle 2-electrode Electrochemical
Measurement Range 0-2 Ppm O2
Purge Time < 6 Hours
Filter None

CatEx 125 PR, Expected sensor life > 4 years, New

Applications:

The CITY AA015-000 gas sensor is suitable for a wide range of applications, including industrial and commercial settings. It can be used in manufacturing facilities, oil and gas refineries, chemical plants, and other industrial environments where there is a risk of gas leakage or exposure. The gas sensor is also useful in laboratories, research facilities, and hospitals, where it can detect hazardous gases and protect personnel and equipment.

The maximum overload of 1000 Ppm O2 provides a high level of safety and protection against dangerous gas levels. The response time (T95) of less than 20 seconds ensures that the gas sensor can quickly detect gas leaks and provide early warning. The purge time of less than 6 hours provides added convenience and ease of maintenance, ensuring that the gas sensor can be cleaned and recalibrated quickly and efficiently.

The CITY AA015-000 gas sensor does not require a filter, making it easy to use and maintain. It is a cost-effective and reliable solution for gas detection, providing accurate and precise readings in a variety of environments.

Overall, the CITY AA015-000 gas sensor is a highly versatile and effective device that can be used in a wide range of applications. Its reliable performance, fast response time, and low maintenance requirements make it an indispensable tool for any facility or organization that needs to monitor gas levels and ensure the safety of its personnel and equipment.

Customization:

  • Brand Name: CITY
  • Model Number: AA015-000
  • Place of Origin: USA
  • Measurement Range: 0-2 Ppm O2
  • Maximum Overload: 1000 Ppm O2
  • Purge Time: < 6 Hours
  • Operating Principle: 2-electrode Electrochemical
  • Response Time (T95): < 20 Seconds

Customization services include:

  • Calibration for specific gas types
  • Adjustment of measurement range
  • Installation of additional features

Contact us at 6812950 to learn more about our product customization services for the New City AA015-000 gas sensor.

Support and Services:

Our Gas Sensor product comes with comprehensive technical support and services to ensure that you get the most out of your purchase.

Our team of experienced technicians is available to provide you with expert advice on installation, maintenance, and troubleshooting. We also offer training and education on the use of our Gas Sensor product to help you maximize its capabilities.

In addition, we provide repair and calibration services to ensure that your Gas Sensor product performs at its best at all times. Our repair services are carried out by highly trained and experienced technicians using only genuine replacement parts.

We also offer a range of accessories and replacement parts to help you maintain and upgrade your Gas Sensor product. Our accessories include mounting brackets, power supplies, and communication cables, among others.

For more information on our Gas Sensor product technical support and services, please contact us.

FAQ:

Q: What is the brand of the gas sensor?

A: The brand of the gas sensor is CITY.

Q: What is the model number of the gas sensor?

A: The model number of the gas sensor is AA015-000.

Q: Where is the gas sensor manufactured?

A: The gas sensor is manufactured in the USA.

Q: What types of gases can the CITY gas sensor detect?

A: The CITY gas sensor can detect a wide range of gases, including carbon monoxide, methane, propane, and natural gas.

Q: Can the CITY gas sensor be used in a commercial setting?

A: Yes, the CITY gas sensor is suitable for both residential and commercial use.


Product Tags:

Precision Electrochemical Gas Sensor

      

2-electrode Electrochemical Gas Sensor

      

AA015-000 Electrochemical Gas Sensor

      
Wholesale AA015-000 CNLH 2-electrode Electrochemical Gas Sensor Precision With 0-2 Ppm O2 Range from china suppliers

AA015-000 CNLH 2-electrode Electrochemical Gas Sensor Precision With 0-2 Ppm O2 Range Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ShenzhenYijiajie Electronic Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0